SUN-5/6/8/10/12/15/20/25K-SG01HP3-EU-AM2 | 5-25kW | Three Phase | 2 MPPT | Hybrid Inverter | HV Battery Supported

The Deye SUN-(5-25)K-SG01HP3-EU Hybrid Inverter series is meticulously engineered to deliver superior performance for modern solar power systems. It caters to a broad spectrum of energy needs with models ranging from 5kW to 25kW, making it suitable for both residential and commercial applications. This inverter series is designed to handle the dynamic requirements of power systems, ensuring reliability, flexibility, and efficiency in energy management.

Categories: ,
  • 100% unbalanced output, each phase
  • AC couple to retrofifit existing solar system
  • *Max. 10 pcs parallel for on-grid and off-grid

    operation; Support multiple batteries parallel

  • Max. charging/discharging current of 50A
  • High voltage battery, higher effificiency
  • 6 time periods for battery charging/discharging
  • Support storing energy from diesel generator

    ModelSUN-5K -SG01HP3-EU-AM2SUN-6K -SG01HP3-EU-AM2SUN-8K -SG01HP3-EU-AM2SUN-10K -SG01HP3-EU-AM2SUN-12K -SG01HP3-EU-AM2SUN-15K -SG01HP3-EU-AM2SUN-20K -SG01HP3-EU-AM2SUN-25K -SG01HP3-EU-AM2
    Battery Input Data
    Battery TypeLithium-ion
    Battery Voltage Range(V)160-700
    Max.Charging Current(A)30303750
    Max.Discharging Current(A)30303750
    Charging Strategy for Li-ion BatterySelf-adaption to BMS
    Number of battery input1
    PV String Input Data
    Max. PV Access Power (W)
    1000012000160002000024000300004000050000
    Max DC Input Power(W)80009600128001600019200240003200040000
    Max DC Input Voltage(V)1000
    Start-up Voltage(V)180
    MPPT Voltage Range(V)150-850
    Rated DC Input Voltage(V)600700
    Max Input Short-Circuit Current(A)30+3039+3039+39
    Max Operating PV Input Current(A)20+2026+2026+26
    No.of MPP Trackers/No.of String Per MPP Tracker2/1+12/2+12/2+2
    AC Input/Output Data
    Rated AC Input/Output Active Power(W)5000600080001000012000150002000025000
    Max AC Input/Output Apparent Power (VA)5500660088001100013200165002200027500
    Peak Power (off-grid)(W)1.5 times of rated power,10s
    Rated AC Input/Output Current(A)7.6/7.39.1/8.712.2/11.615.2/14.518.2/17.422.8/21.830.4/2937.9/36.3
    Max AC Input/Output Current(A)8.4/810/9.613.4/12.816.7/1620/19.225/2433.4/31.941.7/39.9
    Max Continuous AC Passthrough (grid to load)(A)4080
    Rated Input/Output Voltage/Range(V)220/380V,230/400V 0.85Un-1.1Un
    Grid Connection Form3L+N+PE
    Rated Input/Output Grid Frequency/Range50Hz/45Hz-55Hz  60Hz/55Hz-65Hz
    Power Factor Adjustment Range0.8 leading to 0.8 lagging
    Total Current Harmonic Distortion THDi<3% (of nominal power)
    DC Injection Current<0.5%ln
    Efficiency
    Max Efficiency97.6%
    Euro Efficiency97.0%
    MPPT Efficiency>99%
    Equipment Protection
    Integrated
    DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
    AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
    Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
    Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
    DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
    Surge Protection LevelTYPE II(DC),TYPE II(AC)
    Interface
    Communication Interface
    RS485/RS232/CAN
    Monitor Mode
    GPRS/WIFI/Bluetooth/4G/LAN(optional)
    General Data
    Operating Temperature Range
    -40 to +60℃, >45℃ Derating
    Permissible Ambient Humidity0-100%
    Permissible Altitude2000m
    Noise≤ 55 dB(A)
    Ingress Protection(IP) RatingIP 65
    Inverter TopologyNon-Isolated
    Over Voltage CategoryOVC II(DC),OVC III(AC)
    Cabinet size(W*H*D)[mm]408*638*237(Excluding connectors and brackets)
    Weight[kg]30.5
    Warranty
    5 Years/10 Years
    the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
    Type Of Coolingnatural coolingIntelligent air cooling
    Grid RegulationIEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25, G98, G99, VDE-AR-N 4105
    Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2