- 100% unbalanced output;each phase
- AC couple to retrofifit existing solar system
- Max. 10 pcs parallel for on-grid and off-gridoperation; Support multiple batteries parallel
- Max. charging/discharging current of 100A
- High voltage battery, higher efficiency
- 6 time periods for battery charging/discharging
- Support storing energy from diesel generator
Model SUN-29.9K-SG01HP3-EU-BM3 SUN-30K-SG01HP3
-EU-BM3SUN-35K-SG01HP3
-EU-BM3SUN-40K-SG01HP3
-EU-BM4SUN-50K-SG01HP3
-EU-BM4Battery Input Data Battery Type Lithium-ion Battery Voltage Range(V) 160-800 Max.Charging Current(A) 50+50 Max.Discharging Current(A) 50+50 Charging Strategy for Li-ion Battery Self-adaption to BMS Number of battery input 2 PV String Input Data Max. PV Access Power (W)59800 60000 70000 80000 100000 Max DC Input Power(W) 47840 48000 56000 64000 80000 Max DC Input Voltage(V) 1000 Start-up Voltage(V) 180 MPPT Voltage Range(V) 150-850 Rated DC Input Voltage(V) 600 Max Input Short-Circuit Current(A) 55+55+55 55+55+55+55 Max Operating PV Input Current(A) 36+36+36 36+36+36+36 No.of MPP Trackers/No.of String Per MPP Tracker 3/2+2+2 4/2+2+2+2 AC Input/Output Data Rated AC Input/Output Active Power(W) 29900 30000 35000 40000 50000 Max AC Input/Output Apparent Power (VA) 29900 33000 38500 44000 55000 Peak Power (off-grid)(W) 1.5 times of rated power,10s Rated AC Input/Output Current(A) 45.4/43.4 45.5/43.5 53.1/50.8 60.7/58.0 75.8/72.5 Max AC Input/Output Current(A) 45.4/43.4 50/47.9 58.4/55.8 66.7/63.8 83.4/79.8 Max Continuous AC Passthrough (grid to load)(A) 200 Rated Input/Output Voltage/Range(V) 220/380V,230/400V 0.85Un-1.1Un Grid Connection Form 3L+N+PE Rated Input/Output Grid Frequency/Range 50/45-55, 60/55-65 Power Factor Adjustment Range 0.8 leading-0.8 lagging Total Current Harmonic Distortion THDi <3% (of nominal power) DC Injection Current <0.5%ln Efficiency Max Efficiency 97.60% Euro Efficiency 97.0% MPPT Efficiency >99% Equipment Protection IntegratedDC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection levelSurge Protection Level TYPE II(DC), TYPE II(AC) Interface Communication Interface RS485/RS232/CAN Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)General Data Operating Temperature Range -40℃+60℃,>45℃ Derating Permissible Ambient Humidity 0-100% Permissible Altitude 2000m Noise ≤ 65 dB(A) Ingress Protection(IP) Rating IP 65 Inverter Topology Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC) Cabinet size(W*H*D)[mm] 527*894*294(Excluding connectors and brackets) Weight[kg] 80 Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty PolicyType Of Cooling Intelligent air cooling Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
SUN-29.9/30/35/40/50K-SG01HP3-EU-BM3/4 | 29.9-50kW | Three Phase | 2/3/4 MPPT | Hybrid Inverter | HV Battery Supported
The Deye Three Phase Hybrid Inverter series is designed for robust performance and efficient energy management in both residential and commercial settings. With a focus on high efficiency, seamless integration, and advanced protection features, these inverters offer a versatile solution for modern energy needs.